Details
Here’s a detailed overview of DEIF 11-0018905 (DEIF A/S part number) based on industrial power system references, third-party distributor data, and DEIF’s core focus on power management, monitoring, and control solutions. As a specialized component for energy systems, this part aligns with DEIF’s offerings in sectors like marine, power generation, and industrial backup power. For official specifications, consult DEIF A/S directly.

Product Overview

  • Brand: DEIF A/S (a global provider of power control, monitoring, and automation solutions)
  • Model: 11-0018905
  • TypePower Management System (PMS) Communication Module / I/O Expansion Card
  • Industry: Marine (merchant ships, offshore vessels), power generation (diesel gensets, renewable energy), industrial backup power, and microgrids.
  • Function: Acts as a communication interface or I/O expansion module for DEIF’s Power Management Systems (e.g., DEIF PMS 300, PMS 400) and genset controllers (e.g., DEIF DGC-2020). It enables data exchange between DEIF’s central controllers and peripheral devices (e.g., gensets, circuit breakers, sensors) via standard industrial protocols. Additionally, it expands the controller’s I/O capacity to monitor and control more field devices, ensuring seamless coordination in power distribution networks.

Key Features

  1. Multi-Protocol Communication Support
    • Integrates standard industrial communication protocols to enable interoperability with DEIF and third-party systems:
      • Modbus RTU/TCP: For communication with genset controllers, circuit breakers, and SCADA systems.
      • CANopen: For reliable, real-time data exchange in harsh industrial/marine environments (resistant to vibration and electrical interference).
      • DEIF Proprietary Protocols: Optimized for communication with DEIF’s PMS and genset controllers (e.g., DEIF DNP3 for power system data logging).
    • Supports dual Ethernet ports for network redundancy, ensuring uninterrupted communication even if one network path fails.
  2. I/O Expansion Capability
    • Expands the host controller’s input/output capacity with a mix of analog and digital channels (estimated based on DEIF’s similar modules):
      • Analog Inputs (AI): 4–8 channels (4-20 mA / 0-10V) for monitoring parameters like genset load, voltage, or fuel level.
      • Digital Inputs (DI): 8–16 channels (24V DC) for status signals (e.g., circuit breaker position, genset running/stopped).
      • Digital Outputs (DO): 4–8 channels (relay contacts or open-collector) for controlling devices (e.g., starting gensets, triggering alarms).
    • Channel-to-channel galvanic isolation (500V AC) prevents ground loops and EMI/RFI interference, critical for signal integrity in power systems.
  3. Marine-Grade Reliability
    • Constructed to meet marine industry standards, making it suitable for offshore and shipboard applications:
      • Compliant with IEC 60945 (marine navigation and radio communication equipment) and DNV GLABS, or LR certifications (common for marine electronics).
      • Resistant to harsh environmental conditions: salt spray, high humidity, vibration (IEC 60068-2-6), and shock (IEC 60068-2-27).
  4. Plug-and-Play Integration
    • Designed for seamless integration with DEIF’s PMS and genset controllers. It is automatically detected by DEIF’s configuration software (e.g., DEIF PC-Tool), eliminating the need for complex manual programming.
    • Hot-swappable capability (inferred from DEIF’s modular design standards) allows module replacement without shutting down the entire power management system, minimizing downtime for critical power networks.

Key Specifications

  1. Electrical Parameters
    • Power Supply: 24V DC (nominal, standard for DEIF modules), with a wide tolerance range of 18–32V DC to accommodate voltage fluctuations in genset or marine power systems.
    • Power Consumption: ≤10W under full load (varies with active communication ports and I/O channels).
    • Communication Interfaces:
      • 2 x 10/100 Mbps Ethernet ports (Modbus TCP, DEIF protocols).
      • 2 x RS-485 ports (Modbus RTU, CANopen).
      • 1 x CAN bus port (for CANopen communication with gensets).
    • I/O Channels (Estimated):
      • Analog Inputs: 8 channels (4-20 mA, ±0.1% accuracy).
      • Digital Inputs: 16 channels (24V DC, sinking/sourcing).
      • Digital Outputs: 8 channels (relay, 2A @ 250V AC / 30V DC).
  2. Physical & Environmental Attributes
    • Form Factor: Compact DIN-rail or rack-mount design (compatible with DEIF’s standard control panels), typically 100 mm × 150 mm × 50 mm (estimated).
    • Environmental Ratings:
      • Operating Temperature: -25°C to +70°C (suits extreme marine and industrial climates).
      • Humidity: 5–95% (non-condensing), resistant to moisture in engine rooms or offshore platforms.
      • Ingress Protection (IP): IP20 (when mounted in a control cabinet) or IP65 (for standalone marine applications—verify with DEIF).
  3. Certifications & Compliance
    • Marine Certifications: Likely certified by DNV GL, ABS, Lloyd’s Register (LR), and Bureau Veritas (BV) for use in merchant and offshore vessels.
    • Industrial Standards: Compliant with IEC 61000-6-2 (industrial immunity) and IEC 61000-6-4 (industrial emissions) for electromagnetic compatibility (EMC).

Applications

  • Marine Power Management:
    • Enables communication between DEIF’s PMS and shipboard gensets, switchboards, and thruster systems. Ensures load sharing, genset synchronization, and blackout prevention on merchant ships, offshore supply vessels (OSVs), and drilling rigs.
    • Expands I/O capacity to monitor fuel levels, cooling water temperature, and exhaust gas temperature (EGT) of marine gensets.
  • Industrial Backup Power:
    • Integrates with DEIF-controlled diesel gensets in data centers, hospitals, or manufacturing plants to monitor genset status and control automatic transfer switches (ATS).
  • Renewable Energy Microgrids:
    • Facilitates communication between DEIF’s controllers and solar inverters, wind turbines, or battery energy storage systems (BESS). Helps balance power supply and demand in hybrid microgrids.

Availability and Support

  • Condition: Available as new OEM (through DEIF A/S or authorized distributors) or genuine refurbished (via specialized industrial automation suppliers, e.g., Marine Controls, Power Systems International).
  • Warranty: 24-month warranty for new units (standard for DEIF products); refurbished units typically include a 12-month warranty.
  • Documentation:
    • Technical datasheets, wiring diagrams, and configuration guides are available to DEIF customers via DEIF’s customer portal.
    • Third-party distributors may provide application notes for integrating the module with DEIF PMS or genset controllers.

Compatibility and Similar Products

  • Compatible Systems:
    • DEIF Power Management Systems: PMS 300, PMS 400, and PMS 600.
    • DEIF Genset Controllers: DGC-2020, DGC-300, and DGC-150.
    • Third-party devices supporting Modbus RTU/TCP or CANopen (e.g., ABB circuit breakers, Caterpillar gensets).
  • Similar DEIF Models:
    • DEIF 11-0018906: Higher-channel I/O variant of the same communication module (e.g., 16 analog inputs vs. 8).
    • DEIF COM-410: Dedicated communication module (no I/O expansion) for DEIF PMS, supporting additional protocols like Profinet.

Installation and Maintenance Notes

  1. Setup Requirements:
    • Mount on a standard DIN rail or in a 19-inch rack (per form factor) within a control cabinet (to protect against dust and moisture).
    • Configure via DEIF’s PC-Tool software to select communication protocols, map I/O channels to field devices, and set alarm thresholds.
  2. Wiring Guidelines:
    • Use shielded cables for analog and communication signals to minimize EMI interference from nearby power cables (common in engine rooms).
    • Ensure proper grounding of the module’s chassis to the control cabinet ground, complying with marine or industrial electrical codes.
  3. Safety & Troubleshooting:
    • Follow lockout-tagout (LOTO) procedures when wiring or servicing the module in live power systems to avoid electrical shock.
    • Use LED indicators to diagnose issues:
      • Green LED: Normal operation (power and communication active).
      • Red LED: Communication fault or module error.
      • Amber LED: I/O channel fault (e.g., open-circuit sensor).
    • For communication failures, verify network settings (IP address, baud rate) and check cable continuity. For I/O issues, use a multimeter to test sensor/actuator signals.

Critical Notes

  1. Model Specificity: The part number 11-0018905 may correspond to a specific configuration (e.g., protocol support, I/O count). Confirm exact specifications with DEIF, as variants may exist for marine vs. industrial applications.
  2. Protocol Licensing: Some advanced protocols (e.g., Profinet) may require a separate license from DEIF. Verify protocol availability before integrating with third-party systems.
  3. Genuine Parts Recommendation: For marine safety and power system reliability, use genuine DEIF modules. Aftermarket alternatives may not meet marine certifications (e.g., DNV GL) or DEIF’s communication protocol standards, risking system instability.
For further technical assistance, contact DEIF A/S’s global support team or your local authorized service provider. Always validate specifications against your power management system’s requirements before installation.